Sub-Zero Fault Code List (All Series)

Every stored fault code, by series, in plain English, checked against Sub-Zero factory service documentation.

Updated October 2026 · By the Sub-Zero Repair Las Vegas service team · Technical details checked against Sub-Zero factory service documentation (sources)

Quick answer

Sub-Zero fault codes depend on the series. Classic BI models (serial #4380000+) use a three-part code: category (10 thermistor, 15 relay, 20 defrost, 30 ice/water, 35 fan, 40 run time, 45 lights, 50 flow meter, 60 compressor load, 90 control, 95 diagnostics, 98 power), location (1 refrigerator, 2 freezer, F/r evaporators, 8 ice maker, U water) and failure type (00 open, 01 short, 02 unstable). 600, 700 and UC models use EC 05–08 sensors, 20–24 defrost, 30 ice maker valve, 40/50 excessive compressor run. 400-2 wine adds 10–13 temperature alarms and 15 sealed system fault.

These fault codes are stored by Sub-Zero electronic controls and read by a technician. The meanings below are summarized from Sub-Zero factory service documentation so you can understand a diagnosis or an Info-screen error. The troubleshooting steps behind each code (electrical testing, component activation, sealed system work) are for certified technicians and are not reproduced here.

Which Code System Does Your Sub-Zero Use?

SeriesFormatJump to
Classic Built-In (BI-30U, BI-36U, BI-36UFD, BI-36S, BI-42SD, BI-48SD…), serial #4380000 and laterCategory · location · failure, e.g. 10 1 00Classic codes
Integrated tall & column (IT, IC)Same categories, by zone 1–3, with severity levelsIntegrated
600 / 600-2, 700-2 / 700-3, UC Series“EC” + two digits (05–50; 80–88 on 700TF/I-2V)EC codes
400-2 wine storage“EC” + two digits (05–15)Wine codes
648PRO / ICB648PROEC code + zone digit648PRO codes
Original 700 SeriesDisplay indicators only (--, -20, 55, Su, -88)EE & sensor faults

Classic BI Fault Codes (Serial #4380000 and Later)

A Classic code has three parts. The first number is the category, the middle character is the location, and the last two digits are the failure type. For example, 10 1 00 reads “thermistor fault · refrigerator · open”.

CategoryMeaning
10Thermistor (temperature sensor) faults
15Relay faults
20Defrost heater faults
30Ice / water / accessory faults
35Fan faults
40Runtime faults
44Glass heater faults
45Lighting faults
50Flow meter
60Load / component faults
90Control faults
95Diagnostics
98Power faults
LocationMeaning
0Miscellaneous
1Refrigerator
2Freezer
3Condenser
4Defrost system
5Control system
6Compressors
7Ambient (room)
8Ice maker
9Dispenser
AAir purifier
dDrawer
FFreezer evaporator
HHigh-voltage system
LLighting
rRefrigerator evaporator
UWater systems

Common failure types: 00 open, 01 short/closed, 02 unstable, 05/06 mis-wired, 07 bad resistance, 09 too warm / large temperature difference, 33/34 fan speed too low / too high, 38 output fault, 40 excessive run time, 45 burned-out light, 50 open heater, 60 no load, 70–75 memory errors, 80–85 communication and display failures, 86/87 flow too slow / no flow, 98 brownout.

Thermistors

CodeMeaningGuide
10 1 00 / 01 / 02Refrigerator cabinet sensor open / shorted / unstableRelated
10 2 00 / 01 / 02Freezer cabinet sensor open / shorted / unstableRelated
10 3 00 / 01 / 02Condenser sensor open / shorted / unstableRelated
10 7 00 / 01 / 02Ambient (room) sensor open / shorted / unstableRelated
10 F 00 / 01 / 02Freezer evaporator sensor open / shorted / unstableRelated
10 r 00 / 01 / 02Refrigerator evaporator sensor open / shorted / unstableRelated
10 r 09Refrigerator evaporator reads at least 10° warmer than the cabinet sensor: a sensor problem or an evaporator-related problemRelated
10 3 10 / 11 / 12Listed as currently inactive—

Relays (on the control board)

CodeMeaningGuide
15 1 00 / 01Refrigerator compressor relay stuck open (no power to compressor) / stuck closed (power at all times)Related
15 2 00 / 01Freezer compressor relay stuck open / stuck closedRelated
15 4 00 / 01Defrost relay stuck open (no power to defrost heater) / stuck closedRelated
15 8 00 / 01Ice maker relay stuck open / stuck closedRelated
15 8 10 / 11Ice accessories relay (fill tube heater, mullion heater) stuck open / closedRelated
15 9 00 / 01Dispenser auger relay stuck open / closedRelated
15 9 65Water valve selecting relay stuck at the dispenser position: ice making disabledRelated
15 9 66Water valve selecting relay stuck at the ice maker positionRelated
15 L 00 / 01Main lights relay fault (stuck open / stuck closed)Related
15 U 00 / 01Water valve relay stuck open / closedRelated
15 U 10Water check valve relay stuck open or closedRelated
15 L 55 / 56Listed as currently inactive—

Defrost

CodeMeaningGuide
20 2 00Defrost bi-metal (temperature switch) stuck openRelated
20 2 01Defrost bi-metal stuck closedRelated
20 2 05Defrost bi-metal mis-wired: normal temperatures but wrong response during defrostRelated
20 2 06Defrost bi-metal mis-wired: high temperatures and wrong response during defrostRelated
20 2 07Defrost bi-metal error (resistance out of range)Related
20 2 50Defrost heater openRelated

Ice maker, dispenser and water

CodeMeaningGuide
30 8 00Ice accessories open circuit (fill tube heater, and mullion chute heater if equipped)Related
30 8 05No fill signal from the ice makerRelated
30 8 10Ice maker open circuitRelated
30 8 30Water passing through although the water valve was not openedRelated
30 9 01Bulk ice switch stuck closed (pressed more than 5 seconds with the door closed)Related
30 9 10Dispenser auger open circuitRelated
30 9 80Communication problem with the dispenserRelated
30 9 86Ice chute motor did not reach its open or closed position (jammed or blocked)Related
30 U 00Water valve open circuitRelated
30 U 10Dispenser water valve open circuitRelated
30 U 20Water check valve open circuitRelated

Fans

CodeMeaningGuide
35 A 36 / 37Air purifier fan faultRelated
35 F 33Freezer evaporator fan cannot reach full speed (often an obstruction)Related
35 F 34Freezer evaporator fan running faster than its settingRelated
35 r 33Refrigerator evaporator fan cannot reach full speedRelated
35 r 34Refrigerator evaporator fan not running at its settingRelated
35 3 00 / 35Listed as currently inactive—

Run time

CodeMeaningGuide
40 1 40Excessive refrigerator run time. Sub-Zero's checks: door leaks, door ajar, refrigerant charge, iced evaporatorRelated
40 2 40Excessive freezer run time (same checks)Related
40 1 38 / 40 2 38Refrigerator / freezer stepper valve communication faultRelated
40 b 38Baffle stepper communication faultRelated
40 8 40Ice maker reached maximum fill time without enough water: blockages, kinked water line or low water pressureRelated
40 9 40Dispenser ran for its maximum time (150 seconds): stuck key or floodingRelated

Heaters and lights

CodeMeaningGuide
44 0 00 / 01Glass door heater open / short circuitRelated
44 9 42 / 431-watt / 4-watt glasswell heater not detected—
45 1 00 / 01Main refrigerator lights open / short circuit—
45 2 00 / 01Main freezer lights open / short circuit—
45 A 45Air purifier light burned out: replace the air purifier cartridgeRelated
45 L 00 / 01Accent lights open / short circuit—

Water flow meter

CodeMeaningGuide
50 U 80Water flow meter not detectedRelated
50 U 86Flow meter detected low flow: check water pressure and obstructionsRelated
50 U 87Flow meter detected no flow: check water pressure, flow, and that the meter is not blocked or dirtyRelated

Compressors (variable speed)

CodeMeaningGuide
60 1 02 / 38Refrigerator variable-speed compressor communication errorRelated
60 1 60No refrigerator compressor load detectedRelated
60 2 02 / 38Freezer variable-speed compressor communication errorRelated
60 2 60No freezer compressor load detectedRelated

Control and display

CodeMeaningGuide
90 0 70 to 75Control memory (flash) failureRelated
90 0 81 / 90 / 92 / 93Microcontroller faultRelated
90 3 55 / 56Condenser fan control (triac) open / shortedRelated
90 5 01 / 95 / 96Key shorted or damaged on the control panelRelated
90 5 3812-volt fan power output faultRelated
90 5 44Glass door heater output faultRelated
90 5 80No keypad communicationRelated
90 5 85User display failureRelated
90 5 97 / 99Control panel microcontroller problem / control panel errorRelated
90 9 80No communication with the door dispenserRelated
90 A 38Air purifier fan output fault on the control boardRelated
90 b 80No stepper micro communicationRelated
90 F 38Freezer evaporator fan output fault on the control boardRelated
90 r 38Refrigerator evaporator fan output fault on the control boardRelated
90 H 80 / 82 / 83Main board communication problems (82 = intermittent)Related
90 H 84Initialization faultRelated
90 L 38Accent light output faultRelated

Cooling diagnostics and power

CodeMeaningGuide
95 1 25Refrigerator evaporator not cooling properly while the compressor runs: sealed system checkRelated
95 2 25Freezer evaporator not cooling properly while the compressor runs: sealed system checkRelated
95 1 00 / 01, 95 2 00 / 01Compressor control signal stuck off / on (control board)Related
98 0 98Brownout (low-voltage) conditions detected—

Three Classic messages are not part of this table: LO C, H2 LO and dO Or.

Integrated (Designer) Tall & Column Codes

Integrated models (IC-18FI, IC-30R/RID, IC-30FI, IC-36R/RID, IT-30CI, IT-30R, IT-30FI, IT-36FI, IT-36CI, IT-36R and related) use the same category numbers as Classic: 10 thermistor, 15 relay, 20 defrost, 30 ice/water/accessory, 35 fan, 40 runtime, 44 glass heater, 45 lighting, 50 flow meter, 60 load/component, 90 control, 95 diagnostics, 98 power. Locations are zones 1, 2 and 3 plus shared systems (condenser, ambient, ice maker, dispenser, air filter, lighting, water system, high-voltage system, baffle). Fault families include cabinet and evaporator sensors per zone, compressor relays per zone, stepper (cooling) current and cooling faults, excessive run time per zone, evaporator and DC condenser fan faults, defrost bi-metal and heater faults, water valve current faults, lighting, user interface communication and high-voltage micro communication faults.

Each error also has a severity: level 1 is only logged for service; levels 2–3 appear on screen when the door is opened; level 4 also chimes with the door open; level 5 (critical) chimes even with the door closed. Owners can see logged errors under Info → Errors.

600, 700 and UC Series “EC” Codes

CodeMeaning
05Refrigerator cabinet sensor open, shorted or erratic for 10+ seconds
06Refrigerator evaporator sensor open, shorted or erratic for 10+ seconds
07Freezer cabinet sensor open, shorted or erratic for 10+ seconds
08Freezer evaporator sensor open, shorted or erratic for 10+ seconds
20Defrost under-heat, with no voltage feedback at defrost start
21Defrost overheat
22No voltage feedback at defrost start
23Defrost overheat, with no voltage feedback at defrost start
24Defrost under-heat
30Ice maker water valve energized longer than 15 seconds (not applicable on UC and 700-3 base units)
40Excessive freezer compressor run time
50Excessive refrigerator compressor run time (700BC/I: excessive refrigerator fan run)

The 600 Series control from serial #1810000 registers thermistor and defrost codes only (05–08, 20–24). On 700-2 tall units from serial #1759163, codes 80–88 apply to the 700TF/I-2V variable-speed model only (from serial #1898164):

CodeMeaning
80High differential pressure or low voltage at the variable-speed compressor
81High amperage draw at the variable-speed compressor
82Compressor could not hold minimum speed at its highest current draw
83Locked variable-speed compressor rotor
84Short circuit at the compressor controller output
85Compressor inverter overheated and shut the compressor down
86Communication failure between compressor controller and control board
87Speed information from the control board out of specification
88Control board not receiving status data in response to speed commands

400-2 Wine Storage Codes

CodeMeaning
05 / 06Upper cabinet / upper evaporator sensor open, shorted or erratic
07 / 08Lower cabinet / lower evaporator sensor open, shorted or erratic
10 / 11Upper cabinet warm / cold temperature alarm
12 / 13Lower cabinet warm / cold temperature alarm
15Sealed system fault: evaporator could not drop 5° in 5 minutes after three consecutive valve activations

More on wine storage alarms.

648PRO Codes (with Zone Digit)

The second digit identifies where the fault occurred: 0 = a shared component, 1 = zone 1 or the left system, 2 = zone 2, 3 = zone 3 or the right system, 4 = zone 4. Zones 2 and 4 may not be present on every model.

CodeMeaning
01 / 02 / 03Zone X cabinet / evaporator / condenser sensor failure (device or wiring)
04Ambient sensor failure
20 / 21Zone X defrost bi-metal not operating properly
22 / 23Zone X defrost wiring
24Zone X defrost heater resistance
30Stuck ice maker or water valve failure
35Zone X fan speed error
40Zone X excessive run
41Zone X compressor or its wiring
42Condenser fan or its wiring
43Left refrigerant valve or its wiring
44Zone X glass door heater or its wiring
46Ice accessory wiring open circuit
47Accent lighting wiring short circuit
80Power to the zone X compressor controller
83Zone X variable-speed compressor (compressor and filter-drier replacement)
84Zone X variable-speed compressor wiring
85Zone X variable-speed compressor control overheat
86Communication wiring / zone X variable-speed controller
87Broken wiring or open defrost heater
89Ice maker solenoid valve or its wiring
90Main control board
92 / 93Keypad wiring / keypad
94User display wiring or display
96Data logger malfunction
97Communication cables or connectors
98Brownout: check input power supply

You Have a Code: What Next?

  1. Write the full code exactly as shown, with your model and serial number.
  2. Don't clear it. Sub-Zero notes codes return until the fault is repaired, and the history speeds up diagnosis.
  3. On Classic models, if a fault chime is sounding, you can suspend it for 24 hours. See service icon.
  4. Call (725) 237-7399. Tell us the code, and we'll bring the parts it points to.

Sources

  • Sub-Zero Built-In (BI) Classic Series Technical Service Manual, #7040317, Revision A, September 2015 — pp. 7-2 to 7-11, 2-34 to 2-36. Covers: BI-30U, BI-36U/UID/UFD/UFDID, BI-36F, BI-36R, BI-36S, BI-42S/SD/SID, BI-42UFD/UFDID, BI-48S/SD/SID, from serial #4380000.
  • Sub-Zero Integrated Series (Tall & Column) Service Manual, #7028783, Revision E, November 2016 — pp. 7-2 to 7-7. Covers: Designer integrated tall and column models (IT, IC).
  • Sub-Zero Electronic Control Pocketbook (Pocket Manual) — Error Code Tables pp. 20, 46, 57, 71–72, 82, 98, 110–111, 118. Covers: 400/400-2 wine, 427R, 600/600-2, 700/700-2/700-3, 648PRO, UC Series controls.

Sub-Zero service manuals are written for certified technicians. We summarize them in our own words for homeowners and do not reproduce them. Procedures that involve electrical testing, the sealed system or refrigerant are intentionally left out of this page. Model coverage and serial ranges differ between documents, so always match your model and serial number. About our sources

Need a Sub-Zero Specialist?

$75 service call, credited toward your repair · 1-year parts · 180-day labor warranty · EPA 608 certified · Mon–Fri 8am–7pm · Sat–Sun 8am–4pm

Call (725) 237-7399
FAQ

Frequently Asked Questions

What does Sub-Zero code 10 1 00 mean?

On Classic BI models it means the refrigerator cabinet thermistor (temperature sensor) reads open. 10 1 01 is shorted and 10 1 02 is unstable.

What does Sub-Zero code 40 1 40 mean?

Excessive refrigerator run time. Sub-Zero's checks include door leaks, a door left ajar, the refrigerant charge and an iced evaporator.

What is Sub-Zero error code 21?

On 600, 700 and UC controls, EC 21 means defrost overheat.

What does Sub-Zero code 15 mean on a wine cooler?

On 400-2 wine storage, code 15 is a sealed system fault: an evaporator could not drop 5° in 5 minutes after three consecutive valve activations.

Can I clear a Sub-Zero fault code myself?

Sub-Zero intends codes to be cleared after the repair. If the fault is still present, the highest-priority indicator returns, and clearing erases history the technician uses.

Book Sub-Zero Service

Schedule Your Sub-Zero Repair

Call now for the fastest scheduling, or send a request and we'll call you back.

(725) 237-7399

Mon–Fri 8am–7pm · Sat–Sun 8am–4pm

  • ✔ $75 service call, credited toward your repair
  • ✔ 1-year parts & 180-day labor warranty
  • ✔ Upfront quote before any work begins
  • ✔ Sub-Zero parts in stock, so most repairs are finished on the first visit
  • ✔ EPA 608 certified sealed system repair
  • ✔ Repairs of any complexity on current and legacy models

Request Sub-Zero Service

Takes 30 seconds. We'll call to confirm your appointment.

Please enter your name.
Enter a 10-digit phone number.
Enter a 5-digit ZIP code.
Please choose an appliance type.
Please describe the problem (at least a few words).

Service area: the Las Vegas valley and Pahrump (Las Vegas, Henderson, North Las Vegas, Boulder City, Pahrump and nearby communities). By submitting, you agree to be contacted by phone or text about your service request. Privacy

Call Now Book Online