When “EE” appears where a Sub-Zero compartment temperature should be, usually with the SERVICE icon flashing, the control has lost a valid reading from that compartment's temperature sensor (thermistor). Sub-Zero lists the causes as a thermistor or its wiring that is disconnected, shorted or misreading, and, on Classic models, an incorrect model configuration on the control board. It is a technician repair.
Which Side Is Affected
| Series | What you see | Meaning |
|---|---|---|
| Classic BI (from serial #4380000) | “EE” at the left with SERVICE flashing | Freezer compartment thermistor (or its wiring) |
| Classic BI | “EE” at the right with SERVICE flashing | Refrigerator compartment thermistor (or its wiring) |
| 600, 600-2, 700-2, 700-3, UC | “EE” in place of the freezer or refrigerator temperature, SERVICE flashing | That compartment's thermistor |
| 648PRO | “EE” in the freezer, upper or lower refrigerator position | That zone's thermistor |
| 400 / 400-2 wine | “EE” in the upper or lower window, SERVICE flashing | That compartment's thermistor; cooling functions are disabled while error indicators show |
| Original 700 Series | “-20” or “55” instead of a normal reading | Zone thermistor fault (“55” = shorted sensor) |
Why a Sensor Failure Matters
A Sub-Zero control decides when to cool based on its thermistors (electronic temperature sensors). When a compartment sensor reads open, shorted or unstable, the control can no longer regulate that compartment normally and logs a thermistor fault code (for example 10 1 00–10 2 02 on Classic models, or 05–08 on 600/700/UC controls). See the fault code list.
What You Can Do
Safe for homeowners
- Note which side shows EE and take a photo of the display.
- Check food temperatures with a separate thermometer and move perishables if a compartment is warming.
- Keep doors closed and call for service.
Leave to a technician
Checking the sensor and its connections and wiring, and verifying the control board is configured for the correct model. These involve electrical testing behind panels and are not homeowner tasks. See thermistor replacement.
Sources
- Sub-Zero Built-In (BI) Classic Series Technical Service Manual, #7040317, Revision A, September 2015 — pp. 2-34, 7-12 to 7-13. Covers: BI-30U, BI-36U/UID/UFD/UFDID, BI-36F, BI-36R, BI-36S, BI-42S/SD/SID, BI-42UFD/UFDID, BI-48S/SD/SID, from serial #4380000.
- Sub-Zero Electronic Control Pocketbook (Pocket Manual) — pp. 6, 17, 43, 54, 64, 79, 95, 108, 115. Covers: 400/400-2 wine, 427R, 600/600-2, 700/700-2/700-3, 648PRO, UC Series controls.
Sub-Zero service manuals are written for certified technicians. We summarize them in our own words for homeowners and do not reproduce them. Procedures that involve electrical testing, the sealed system or refrigerant are intentionally left out of this page. Model coverage and serial ranges differ between documents, so always match your model and serial number. About our sources